7technology applications – Lenze 8400 motec User Manual
Page 231
Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
231
7
Technology applications
7.3
TA "Actuating drive speed (AC Drive Profile)"
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Configuration parameters for digital control signals:
Configuration parameters for analog setpoints:
Setting parameters:
Display parameter:
Parameter
Selection of signal source
(Lenze setting)
for control signal:
bCInh
)
0: Not connected
bFailReset
)
:
bCinh
Parameter
Selection of signal source
(Lenze setting)
for setpoint selection:
nMainSetValue_a
)
80:
Out1
Main setpoint via fieldbus (Ref from Net)
• 100 % ≡ reference speed (
)
nAuxSetValue_a
)
10:
nIn1_a
Local main setpoint
• 100 % ≡ reference speed (
)
nAuxTorqueValue_a
)
82:
Out1
Torque setpoint via fieldbus (Ref from Net)
nTorqueMotLim_a
)
22:
nC472_3_a
Torque limitation in motor mode
nTorqueGenLim_a
)
23:
nC472_4_a
Torque limitation in generator mode
Parameter
Lenze setting
for setpoint selection:
Drive mode
)
1: Speed mode
This parameter is set by the EtherNet/IP™
Communication Unit and should not be written by the
user.
Parameter
Info
nNset_a
)
Input value of setpoint generator
• 100 % ≡ reference speed (
nOut_a
)
Output value of setpoint generator
• 100 % ≡ reference speed (
Speed setpoint
Speed setpoint for motor control
• 100 % ≡ reference speed (
nTorqueMotLimit_a
)
Torque limitation in motor mode
• 100 % ≡ maximum torque (
)
nTorqueGenLimit_a
)
Torque limitation in generator mode
• 100 % ≡ maximum torque (
)