1 parameter change-over, Parameter change-over, Parameter – Lenze 8400 motec User Manual
Page 263: Change-over, Functio, Ls_writeparamlist, Functions, 8basic functions

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
263
8
Basic functions
8.1
Parameter change-over
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8.1
Parameter change-over
This basic function provides a change-over for up to 16 freely selectable parameters between two
sets with different parameter values.
The parameter list is created in the same way as the user menu is composed, namely by means of
parameterisation. In the »Engineer«, a user-friendly parameterisation dialog with import and
export functions is available for this purpose.
8.1.1
Configuring the list using the »Engineer« parameterisation dialog
In the »Engineer«, a parameterisation dialog is available for user-friendly creation of the parameter
list and entry of the parameter values:
How to get to the parameterisation dialog:
1. »Engineer« Go to the Project view and select the 8400 motec controller.
2. Select the Application parameters tab from the Workspace.
3. Go to the Overview dialog level and click the "Basic functions" button.
4. Go to the Overview Basic functions dialog box and click the Parameter change-over
button.
Parameterisation dialog in the »Engineer«