C00598 | resp. to open circuit ainx, C00600 | resp. to dc bus undervoltage, C00601 | del. resp.to fault: dc bus overvoltage – Lenze 8400 motec User Manual
Page 386: C00600/1, Igger in, C00601/1, Has elapsed (if, C00598/1, C00601, 11 parameter reference

11
Parameter reference
11.2
Parameter list | C00598
386
Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00598
C00600
C00601
Parameter | Name:
C00598 | Resp. to open circuit AINx
Data type: UNSIGNED_8
Index: 23977
d
= 5DA9
h
Configuration of monitoring the analog input
Selection list
0 No Reaction
1 Fault
2 Trouble
4 WarningLocked
Subcodes
Lenze setting
Info
C00598/1
1: Fault
Response to open circuit at AIN1 if configured as
4 ... 20 mA current loop
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00600 | Resp. to DC bus undervoltage
Data type: UNSIGNED_8
Index: 23975
d
= 5DA7
h
Configuration of monitoring of the motor control (group 3)
Selection list
1 Fault
2 Trouble
Subcodes
Lenze setting
Info
C00600/1
2: Trouble
Response to DC bus undervoltage
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00601 | Del. resp.to fault: DC bus overvoltage
Data type: UNSIGNED_16
Index: 23974
d
= 5DA6
h
Error response delay times
Setting range
(min. value | unit | max. value)
0.00
s
65.00
Subcodes
Lenze setting
Info
C00601/1
2.00 s
Delay time for triggering the "DC-bus overvoltage" error
• If a DC-bus overvoltage occurs, an error will not be
triggered until the set delay time has elapsed.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000