C02589 | holding brake: time system, C02593 | holding brake: activation time, C02589/1 – Lenze 8400 motec User Manual
Page 424: C02589/2, C02593/1, C02593/2, C02589, Deactivated, 11 parameter reference
11
Parameter reference
11.2
Parameter list | C02589
424
Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02589
C02593
Bit 7 Reserved
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C02582 | Holding brake: Setting
Data type: UNSIGNED_8
Index: 21993
d
= 55E9
h
Parameter | Name:
C02589 | Holding brake: Time system
Data type: UNSIGNED_16
Index: 21986
d
= 55E2
h
Operating times of the holding brake
• The electromechanical delay times of the holding brake are specified in the data sheets or on the holding brake
nameplate.
Setting range
(min. value | unit | max. value)
0
ms
60000
Subcodes
Lenze setting
Info
C02589/1
100 ms
Holding brake: Application time
• Time in which the holding brake is completely applied
from the beginning of control and in which the
controller is inhibited.
C02589/2
100 ms
Holding brake: Release time
• Time in which the holding brake is completely
released from the beginning of control.
C02589/3
0 ms
Reserved
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C02593 | Holding brake: Activation time
Data type: UNSIGNED_32
Index: 21982
d
= 55DE
h
Time parameter for the delay of trigger signals of the holding brake control
Setting range
(min. value | unit | max. value)
0.0
s
3600.0
Subcodes
Lenze setting
Info
C02593/1
0.0 s
Holding brake: Actual value monitoring
• Time in which the actual value is supposed to reach
the threshold for closing the brake if the setpoint has
already reached the threshold.
• Time > 0 s: If the actual speed value has not reached
the threshold within the time for brake application,
the holding brake is applied by control.
• Time = 0 s: The brake is only applied by control when
the actual speed has reached the application
threshold.
C02593/2
0.0 s
Holding brake: Application delay
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000