Parameter reference
11.2
Parameter list | C00076
346
Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00076
C00079
C00081
C00084
Parameter | Name:
C00076 | Ti current controller
Data type: UNSIGNED_16
Index: 24499
d
= 5FB3
h
From version 03.00.00
Reset time Ti of the current controller for certain inverter functions (parameter identification, flying restart circuit)
• After the motor to be used has been selected from the motor catalogue, the suitable value can be entered
automatically.
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
ms
500.00 10.61 ms
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00079 | SC: Settings
Data type: UNSIGNED_8
Index: 24496
d
= 5FB0
h
From version 04.00.00
Configuration of different options for sensorless control for synchronous motors (
)
Selection list
0 Off
1 On
Subcodes
Lenze setting
Info
C00079/1
0: Off
Reserved
C00079/2
0: Off
Reserved
C00079/3
0: Off
Reserved
C00079/4
1: On
Field weakening for synchronous motors
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00081 | Rated motor power
Data type: UNSIGNED_16
Index: 24494
d
= 5FAE
h
This value can be obtained from the motor nameplate. After the motor to be used has been selected from the motor
catalogue, the suitable value can be entered automatically.
Note:
It is mandatory to give the rated motor power for the sensorless vector control (
).
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
kW
99.00 11.00 kW
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00084 | Motor stator resistance
Data type: UNSIGNED_32
Index: 24491
d
= 5FAB
h
After the motor to be used has been selected from the motor catalogue, the suitable value can be entered
automatically. An automatic detection via the motor parameter identification is possible as well.
Setting range
(min. value | unit | max. value)
Lenze setting
0
mohm
200000 330 mohm
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1