11 parameter reference, 5 table of attributes 436 – Lenze 8400 motec User Manual
Page 436

11
Parameter reference
11.5
Table of attributes
436
Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
L_NSet_1: Max. skip freq.
Linear value
23943
5D87
A
3
INTEGER_16
100
L_NSet_1: Min. skip freq.
Linear value
23942
5D86
A
3
INTEGER_16
100
L_NSet_1: wState
Bit coded
23941
5D85
E
1
UNSIGNED_16
1
L_Compare_1: Fct.
Selection list
23895
5D57
E
1
UNSIGNED_8
1
L_Compare_1: Hysteresis
Linear value
23894
5D56
E
1
INTEGER_16
100
L_Compare_1: Window
Linear value
23893
5D55
E
1
INTEGER_16
100
LA_NCtrl: Analog connection list
Selection list
23875
5D43
A
19
UNSIGNED_16
1
LA_NCtrl: Digital connection list
Selection list
23874
5D42
A
35
UNSIGNED_16
1
L_DigitalDelay_1: Delay
Linear value
23855
5D2F
A
2
UNSIGNED_32
1000
L_DigitalDelay_2: Delay
Linear value
23854
5D2E
A
2
UNSIGNED_32
1000
Current switching frequency
Selection list
23850
5D2A
E
1
UNSIGNED_8
1
L_JogCtrlExtension_1: Digital connection
list
Selection list
23814
5D06
A
11
UNSIGNED_16
1
L_MPot_1: Upper limit
Linear value
23775
5CDF
E
1
INTEGER_16
100
L_MPot_1: Lower limit
Linear value
23774
5CDE
E
1
INTEGER_16
100
L_MPot_1: Acceleration time
Linear value
23773
5CDD
E
1
UNSIGNED_16
10
L_MPot_1: Deceleration time
Linear value
23772
5CDC
E
1
UNSIGNED_16
10
L_MPot_1: Inactive fct.
Selection list
23771
5CDB
E
1
UNSIGNED_8
1
L_MPot_1: Init fct.
Selection list
23770
5CDA
E
1
UNSIGNED_8
1
L_MPot_1: Use
Selection list
23769
5CD9
E
1
UNSIGNED_8
1
L_DigitalLogic_1: Function
Selection list
23755
5CCB
E
1
UNSIGNED_8
1
L_DigitalLogic_1: Truth table
Selection list
23754
5CCA
A
4
UNSIGNED_8
1
L_DigitalLogic_2: Function
Selection list
23753
5CC9
E
1
UNSIGNED_8
1
L_DigitalLogic_2: Truth table
Selection list
23752
5CC8
A
4
UNSIGNED_8
1
16-bit analog input
Linear value
23745
5CC1
A
15
INTEGER_16
100
16-bit common input
Bit coded
23744
5CC0
A
3
UNSIGNED_16
1
8-bit input
Selection list
23742
5CBE
A
49
UNSIGNED_8
1
Network MCI/CAN input words
Bit coded
23699
5C93
A
8
UNSIGNED_16
1
Output words Network MCI/AN
Bit coded
23698
5C92
A
8
UNSIGNED_16
1
LP_Network_InOut: Inversion
Bit coded
23685
5C85
A
4
UNSIGNED_16
1
Speed limitation
Linear value
23666
5C72
A
2
INTEGER_16
100
Frequency limitation
Linear value
23665
5C71
A
2
UNSIGNED_16
1
Field-oriented motor currents
Linear value
23638
5C56
A
1
INTEGER_16
100
PSM: Maximum motor current field
weakening
Linear value
23637
5C55
E
1
UNSIGNED_16
100
Ultimate motor current
Linear value
23636
5C54
E
1
UNSIGNED_16
10
Max. motor speed
Linear value
23610
5C3A
E
1
UNSIGNED_16
1
VFC: V/f +encoder limitation
Linear value
23604
5C34
A
2
UNSIGNED_16
100
VFC: Vp V/f +encoder
Linear value
23603
5C33
E
1
UNSIGNED_16
1000
VFC: Ti V/f +encoder
Linear value
23602
5C32
E
1
UNSIGNED_16
10
VFC-ECO: Vp
Linear value
23600
5C30
E
1
UNSIGNED_16
1000
VFC-ECO: Ti
Linear value
23599
5C2F
E
1
UNSIGNED_16
10
VFC-ECO: Minimum voltage V/f
Linear value
23598
5C2E
E
1
UNSIGNED_8
1
VFC-ECO: Motor voltage Sub
Linear value
23597
5C2D
E
1
INTEGER_16
1
Cosine phi
Linear value
23596
5C2C
A
2
INTEGER_16
100
Output power
Linear value
23595
5C2B
A
2
INTEGER_32
1000
Energy display
Linear value
23594
5C2A
A
2
INTEGER_32
100
VFC-ECO: Motor voltage Sub ramp
Linear value
23593
5C29
E
1
UNSIGNED_8
10
Motor flux Add
Linear value
23591
5C27
E
1
INTEGER_16
100
Inverter motor brake: nAdd
Linear value
23588
5C24
E
1
INTEGER_16
1
Flying restart fct.: Activate
Selection list
23585
5C21
E
1
UNSIGNED_8
1
Code
Name
Type
Index
Data
dec
hex
DS
DA
DT
Factor
CINH
Grayed out = display parameter (read access only)