3 ta "actuating drive speed (ac drive profile), Ta "actuating drive speed (ac drive profile), 7technology applications – Lenze 8400 motec User Manual
Page 229

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
229
7
Technology applications
7.3
TA "Actuating drive speed (AC Drive Profile)"
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.3
TA "Actuating drive speed (AC Drive Profile)"
This function extension is only available from version 04.01.00!
The EtherNet/IP™ Communication Unit supports the "AC Drive Profile".
When you use the Communication Unit EtherNet/IP™, set the "AC Drive Profile" application. The
process data word received by the master control is then interpreted as
• The setting to be made for this in
depends on the firmware:
8400 motec
Communication Unit
EtherNet/IP™
Setting required in C00005:
Version 04.01.00
Version 01.01
"9000: AC Drive Profile"
Version 01.02
"1100: Speed actuating drive (AC Drive Profile)" (recommendation)
or
"9000: AC Drive Profile"
From version
05.00.00
From version 01.01
"1100: Speed actuating drive (AC Drive Profile)" or
"9000: AC Drive Profile" ("1100" is always set)
Detailed information on the "AC Drive Profile" can be found in the EtherNet/IP™
communication manual.