395

11

Parameter reference

11.2

Parameter list | C00720

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00720

C00721

C00725

C00729

Parameter | Name:

C00720 | L_DigitalDelay_1: Delay

Data type: UNSIGNED_32

Index: 23855

d

= 5D2F

h

Switch-on/off delay time
Setting range

(min. value | unit | max. value)

0.0

s

3600.0

Subcodes

Lenze setting

Info

C00720/1

0.0 s

L_DigitalDelay_1

: ON delay

C00720/2

0.0 s

L_DigitalDelay_1

: OFF delay

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000

Parameter | Name:

C00721 | L_DigitalDelay_2: Delay

Data type: UNSIGNED_32

Index: 23854

d

= 5D2E

h

Setting range

(min. value | unit | max. value)

0.0

s

3600.0

Subcodes

Lenze setting

Info

C00721/1

0.0 s

L_DigitalDelay_2

: ON delay

C00721/2

0.0 s

L_DigitalDelay_2

: OFF delay

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000

Parameter | Name:

C00725 | Current switching frequency

Data type: UNSIGNED_8

Index: 23850

d

= 5D2A

h

Display of the current switching frequency

• When a variable switching frequency is selected in

C00018

, the switching frequency may change as a function

of the load and rotational frequency.

Selection list

(read only)

0 2 kHz
1 4 kHz
2 8 kHz
3 16 kHz

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00729 | Keypad/PC: Speed setpoint

Data type: INTEGER_16

Index: 23846

d

= 5D26

h

This code is for device-internal use only and must not be written to by the user!