C01351
Parameter | Name:
C01351 | ACDrive: Control word
Data type: UNSIGNED_16
Index: 23224
d
= 5AB8
h
From version 04.01.00
Display of the "AC Drive profile" control word for the 8400 motec
• If required, you can set an inversion for individual control bits in
which is included in this display.
• Detailed information on the "AC Drive Profile" can be found in the EtherNet/IP™ communication manual.
Display area
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Info
Bit 0 Run Forward
Connections between Run1 and Run2 and trigger events
can be found in the EtherNet/IP™ communication
manual.
Bit 1 Run Backward
Bit 2 Fault Reset
0->1 ≡ Reset error
0 ≡ No response
Bit 3 Reserved
Bit 4 Reserved
Bit 5 NetCtrl
Run/Stop control
0 ≡ Run/Stop control via local setting in the device or
terminal
1 ≡ Run/Stop control via network (e.g. from the scanner)
Bit 6 NetRef
Status of the reference speed / reference torque
0 ≡ Reference via local setting in the device or terminal
1 ≡ Reference via network (e.g. from the scanner)
Bit 7 Reserved
Bit 8 Reserved
Bit 9 Reserved
Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved