C00466 | keypad: default parameter, C00467 | keypad: default welcome screen, C00469 | keypad: fct. stop key – Lenze 8400 motec User Manual
Page 377: C00470 | ls_parfree_b, 11 parameter reference

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
377
11
Parameter reference
11.2
Parameter list | C00466
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00466
C00467
C00469
C00470
Parameter | Name:
C00466 | Keypad: Default parameter
Data type: INTEGER_32
Index: 24109
d
= 5E2D
h
Setting of the default parameter for the keypad
Setting range
(min. value | unit | max. value)
Lenze setting
0
65535 51
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00467 | Keypad: Default welcome screen
Data type: INTEGER_32
Index: 24108
d
= 5E2C
h
Selection of the welcome screen for the keypad
Selection list
(Lenze setting printed in bold)
0 Main menu
1 Parameter list
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00469 | Keypad: Fct. STOP key
Data type: INTEGER_32
Index: 24106
d
= 5E2A
h
Selection of the function for the STOP key on the keypad
Selection list
(Lenze setting printed in bold)
Info
0 No response
STOP key does not have any function
1 Inhibit controller
STOP key sets controller inhibit in the drive
2 Activate quick stop
STOP key sets quick stop in the drive
4 Inhibit controller and reset errors
From version 05.00.00
STOP key sets controller inhibit in the drive and errors are
reset.
5 Activate quick stop and reset errors
From version 05.00.00
STOP key sets quick stop in the drive and errors are reset.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00470 | LS_ParFree_b
Data type: UNSIGNED_8
Index: 24105
d
= 5E29
h
SB: Setting of the signal level to be output
Selection list
0 False
1 True
Subcodes
Lenze setting
Info
C00470/1
0: FALSE
Signal level for output bPar1 ... bPar16
C00470/...
C00470/16
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1