C01911 | function dip switch s1, C01911, Ters – Lenze 8400 motec User Manual
Page 419: 11 parameter reference

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
419
11
Parameter reference
11.2
Parameter list | C01911
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01911
Parameter | Name:
C01911 | Function DIP switch S1
Data type: UNSIGNED_8
Index: 22664
d
= 5888
h
Bit coded display of the DIP1 switch setting
Note:
• Settings made by DIP1, DIP2, P1, P2 and P3 must be activated with the DIP1/switch 1. The settings are accepted
anew every time the mains is switched on. As a consequence, interim changes of parameters may be
overwritten.
• Information on how to commission the 8400 motec via the DIP switches/potentiometers can be found in the
mounting instructions!
Display area
(min. hex value | max. hex value)
0x00
0xFF
Value is bit-coded:
Info
Bit 0 DIP1: DIP switch activated
"1" ≡ Settings according to DIP1, DIP2, P1, P2 and P3 are
active.
•
and
(acceleration/deceleration time)
are overwritten with the setting of potentiometer P3.
•
(fixed setpoint 1) is overwritten with the
setting of potentiometer P2.
Bit 1 DIP2: Direction of rotation inverted
(bSetSpeedCcw) is overwritten:
"0" ≡ bSetSpeedCcw = unchanged
"1" ≡ bSetSpeedCcw = TRUE (Ccw active)
Bit 2 DIP3: V/f setting: 0:linear; 1: square-
law
is overwritten:
"0" ≡ linear
"1" ≡ square-law
Bit 3 DIP4: Flying restart process activated
is overwritten:
"0" ≡ Flying restart process deactivated
"1" ≡ Flying restart process activated
Bit 4 DIP5: Reserved
Bit 5 DIP6: Reserved
Bit 6 DIP7: Reserved
Bit 7 DIP8: Configuration relay; DO1:
0:C621/1=50; 1:C621/2=50
are overwritten:
"0" ≡ DO1=DriveReady / relay=DriveFail
"1" ≡ DO1=DriveFail / relay=DriveReady
Read access Write access CINH PLC STOP No transfer COM MOT