Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00488
C00495
C00496
Parameter | Name:
C00488 | L_JogCtrlExtension_1: EdgeDetect
Data type: UNSIGNED_8
Index: 24087
d
= 5E17
h
From version 05.00.00
FB: Signal methodology
• Selection whether the corresponding function is to be activated by edge or level.
Selection list
0 Level
1 Edge
Subcodes
Lenze setting
Info
C00488/1
0: Level
: InputSens.SlowDown1
• Selection of edge or level for starting slow-down
function 1
C00488/2
0: Level
: InputSens.Stop1
• Selection of edge or level for stop function 1
C00488/3
0: Level
: InputSens.SlowDown2
• Selection of edge or level for starting slow-down
function 2
C00488/4
0: Level
: InputSens.Stop2
• Selection of edge or level for stop function 2
C00488/5
0: Level
: InputSens.SlowDown3
• Selection of edge or level for starting slow-down
function 3
C00488/6
0: Level
: InputSens.Stop3
• Selection of edge or level for stop function 3
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00495 | Speed sensor selection
Data type: UNSIGNED_8
Index: 24080
d
= 5E10
h
From version 02.00.00
Selection of the feedback system for the actual speed for motor control and display
Selection list
(Lenze setting printed in bold)
Info
0 No sensor
No sensor available for the actual speed detection
1 Sensor signal FreqIn12
Speed sensor signal is fed via the digital DI1 and DI2
inputs
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00496 | Encoder evaluation method
Data type: UNSIGNED_8
Index: 24079
d
= 5E0F
h
From version 02.00.00
Selection list
(Lenze setting printed in bold)
Info
1 Low-resolution encoder
High-precision procedure for low-resolution encoders
(<=128 increments)
3 Edge-counting procedure
Simple edge counting procedure with adjustable
scanning time (
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1