Df10: time out i/o micro [xx.0145.00010, Df11: oscillator fail [xx.0145.00011, Df12: math error [xx.0145.00012 – Lenze 8400 motec User Manual
Page 315: Df13: dma error [xx.0145.00013, Ioc: comm module changed [xx.0145.00198, Xx.0145.00010, Xx.0145.00011, Xx.0145.00012, Xx.0145.00013, Xx.0145.00198

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
315
9
Diagnostics & error management
9.8
Error messages of the operating system
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
dF10: time out I/O micro [xx.0145.00010]
dF11: oscillator fail [xx.0145.00011]
dF12: math error [xx.0145.00012]
dF13: DMA error [xx.0145.00013]
IoC: Comm module changed [xx.0145.00198]
Response (Lenze setting printed in bold)
No Reaction Fault Trouble WarningLocked
Cause
Remedy
Device error
• Make sure that the Drive Unit and the Communica-
tion Unit are connected correctly to each other. Check
the pins of the COM plug and firmly tighten all screws
of the 8400 motec cover.
• Mains switching or restart of the controller, respec-
tively.
• Please contact Lenze if the problem occurs again.
Response (Lenze setting printed in bold)
No Reaction Fault Trouble WarningLocked
Cause
Remedy
Device error
• Mains switching or restart of the controller, respec-
tively.
• Please contact Lenze if the problem occurs again.
Response (Lenze setting printed in bold)
No Reaction Fault Trouble WarningLocked
Cause
Remedy
Device error
• Mains switching or restart of the controller, respec-
tively.
• Please contact Lenze if the problem occurs again.
Response (Lenze setting printed in bold)
No Reaction Fault Trouble WarningLocked
Cause
Remedy
Device error
• Mains switching or restart of the controller, respec-
tively.
• Please contact Lenze if the problem occurs again.
Response (Lenze setting printed in bold)
No Reaction Fault Trouble WarningLocked
Cause
Remedy
Since the last power-down, the Communication Unit has
been replaced. The fieldbus, the safety circuit or the
module type has changed. It cannot be assumed any-
more that the available parameter setting matches the
new Communication Unit.
Switch off the device and mount the previous Communi-
cation Unit again. Then acknowledge the error with the
= "1: On / start" device command. All com-
munication parameters in the device will be set to the
Lenze setting of the currently used Communication Unit.
Changed communication parameters must be reset and
saved.