C00471 | ls_parfree, C00472 | ls_parfree_a, C00480 | ls_disfree_b – Lenze 8400 motec User Manual
Page 378: The free, C00472/3, Paramet, C472/3, 11 parameter reference
![background image](/manuals/566305/378/background.png)
11
Parameter reference
11.2
Parameter list | C00471
378
Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00471
C00472
C00480
Parameter | Name:
C00471 | LS_ParFree
Data type: UNSIGNED_16
Index: 24104
d
= 5E28
h
SB: Setting of the words to be output
Setting range
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Bit 0 Active
... ...
Bit 15 Active
Subcodes
Lenze setting
Info
C00471/1
0x0000
Value for output wPar1 ... wPar4
C00471/...
C00471/4
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00472 | LS_ParFree_a
Data type: INTEGER_16
Index: 24103
d
= 5E27
h
SB: Setting of the analog signals to be output
Setting range
(min. value | unit | max. value)
-199.9
%
199.9
Subcodes
Lenze setting
Info
C00472/1
0.0 %
Value for output nPar1_a
C00472/2
0.0 %
Value for output nPar2_a
C00472/3
100.0 %
Value for output nPar3_a
C00472/4
100.0 %
Value for output nPar4_a
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00480 | LS_DisFree_b
Data type: UNSIGNED_8
Index: 24095
d
= 5E1F
h
SB: Display of the input values
Display area
(min. hex value | max. hex value)
0x00
0xFF
Value is bit-coded:
Info
Bit 0 bDis1
Signal level input bDis1 ... bDis8
... ...
Bit 7 bDis8
Read access Write access CINH PLC STOP No transfer COM MOT