C00175
C00177
C00178
C00179
Parameter | Name:
C00175 | Brake energy management: Selection of the braking procedure
Data type: UNSIGNED_8
Index: 24400
d
= 5F50
h
Selection of the braking procedure
Select response if the brake resistor is controlled
Selection list
(Lenze setting printed in bold)
Info
0 Brake resistor
The brake resistor is used. The external brake resistor is
triggered via a hardware circuit. The DC-bus voltage has
no influence on the brake ramp.
2 Brake resistor and stop of the ramp
function generator
The brake resistor and the "Ramp function generator
stop" signal are used. If the brake chopper threshold is
exceeded, the ramp function generator is stopped.
4 Brake resistor and motor brake and
ramp stop
From version 02.00.00
The brake resistor as well as the "Ramp function
generator stop" signal and the "Inverter motor brake"
function are used.
6 Brake resistor and motor
From version 02.00.00
The brake resistor is used. The braking energy is
degraded by overmagnetising the motor by the
.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00177 | Switching cycles
Data type: UNSIGNED_32
Index: 24398
d
= 5F4E
h
Counter of different switching cycles and stressful situations
Display range
(min. value | unit | max. value)
0
2147483647
Subcodes
Info
C00177/1
Number of mains switching cycles
C00177/2
Number of switching cycles of the output relay
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00178 | Elapsed-hour meter
Data type: UNSIGNED_32
Index: 24397
d
= 5F4D
h
Display of operating hours in seconds
Display range
(min. value | unit | max. value)
0
s
2147483647
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00179 | Power-on time meter
Data type: UNSIGNED_32
Index: 24396
d
= 5F4C
h
Display of the power-on time in seconds
Display range
(min. value | unit | max. value)
0
s
2147483647
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1