C00123
C00129
C00130
C00131
C00133
Parameter | Name:
C00123 | Device utilisation threshold (Ixt)
Data type: INTEGER_16
Index: 24452
d
= 5F84
h
Operating threshold for the "OC5: Device overload (Ixt)" error message
• The response for reaching the threshold can be selected in
• The current device utilisation is displayed in
Setting range
(min. value | unit | max. value)
Lenze setting
0
%
200 100 %
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00129 | Brake resistance value
Data type: UNSIGNED_16
Index: 24446
d
= 5F7E
h
Resistance value of the connected brake resistor
• The value to be entered can be obtained from the nameplate of the brake resistor.
Settings for internal brake resistor E84DZEWxxxx
Setting range
(min. value | unit | max. value)
Lenze setting
0.0
Ohm
500.0 220.0 Ohms
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10
Parameter | Name:
C00130 | Rated power - brake resistor
Data type: UNSIGNED_16
Index: 24445
d
= 5F7D
h
Rated power of the connected brake resistor
• The value to be entered can be obtained from the nameplate of the brake resistor.
Settings for internal brake resistor E84DZEWxxxx
Setting range
(min. value | unit | max. value)
Lenze setting
0
W
65535 15 W
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00131 | Thermal capacity - brake resistor
Data type: UNSIGNED_16
Index: 24444
d
= 5F7C
h
Thermal capacity of the connected brake resistor
• The value to be entered can be obtained from the nameplate of the brake resistor.
Settings for internal brake resistor E84DZEWxxxx
Setting range
(min. value | unit | max. value)
Lenze setting
0.0
kWs
6553.5 0.6 kWs
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10
Parameter | Name:
C00133 | Brake resistor utilisation
Data type: UNSIGNED_16
Index: 24442
d
= 5F7A
h
Display of the utilisation of the connected brake resistor
Display range
(min. value | unit | max. value)
0
%
65535
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1