8basic functions – Lenze 8400 motec User Manual
Page 270
![background image](/manuals/566305/270/background.png)
8
Basic functions
8.2
Holding brake control
270
Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Input and output signals of the holding brake control:
Short overview of parameters for holding brake control:
Input
Data type
Configuration parameters
Information/possible settings
bBrkRelease
BOOL
Manual release of the brake in connection with the selected operating mode.
• In the Lenze setting, this input is connected to the digital input DI5.
FALSE Do not release the brake manually.
TRUE Release brake manually (forced release).
• Note!
The brake can also be released if the controller is inhibited!
• During automatic operation, the internal brake logic is
deactivated and the brake is released (supervisor operation). If a
controller inhibit has been set by the brake control, it will be
deactivated.
• In semi-automatic operation, the brake is released including
feedforward control.
Output
Data type
Value/meaning
bBrkReleaseOut
BOOL
Trigger signal for the motec-internal power output (terminals BR1 and BR2) for
triggering the brake.
• Use bit 0 in
to activate inverted triggering of the power output.
FALSE Apply brake.
TRUE Release brake.
bBrkReleased
BOOL
"Brake released" status signal considering the brake release time
• When the holding brake is triggered to close, bBrkReleased is immediately set to
FALSE even if the brake closing time has not yet elapsed!
TRUE Brake released (after the brake release time has expired).
Parameter
Info
Lenze setting
Value Unit
Signal source for bBrkRelease
15: DigIn_bIn5
Holding brake: Operating mode
0: Brake control off
Holding brake: Switching threshold
5.00 %
Holding brake: Hyst. release
1.00 %
Holding brake: Hyst. close
1.00 %
Holding brake: Setting
0
Holding brake: Closing time
100 ms
Holding brake: Release time
100 ms
Holding brake: Actual value monitoring
0.000 ms
Holding brake: Application delay
0.000 ms
MCK: Holding brake ramp time synchr.
2.0 s
Holding brake: Status
-
Cause of controller inhibit
Bit 12: Automatic brake operation
-
MCK: bBrkRelease
-
Highlighted in grey = display parameter