C00159 | cause of quick stop qsp, C00160 | status determining error, C00161 | status determining error – Lenze 8400 motec User Manual
Page 361: C00159, Displays a bit code, C00161/1, C00160/1, 11 parameter reference
![background image](/manuals/566305/361/background.png)
Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
361
11
Parameter reference
11.2
Parameter list | C00159
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00159
C00160
C00161
Parameter | Name:
C00159 | Cause of quick stop QSP
Data type: UNSIGNED_16
Index: 24416
d
= 5F60
h
Bit coded display of the cause/source of the quick stop
Display area
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Bit 0 Terminal
Bit 1 Reserved
Bit 2 DriveControl Network MCI/CAN
Bit 3 Reserved
Bit 4 Application
Bit 5 Device command
Bit 6 Reserved
Bit 7 Reserved
Bit 8 Reserved
Bit 9 Reserved
Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00160 | Status determining error
Data type: UNSIGNED_16
Index: 24415
d
= 5F5F
h
Display range
(min. value | unit | max. value)
0
65535
Subcodes
Info
C00160/1
Status determining error (16-bit)
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00161 | Status determining error
Data type: UNSIGNED_32
Index: 24414
d
= 5F5E
h
Display range
(min. value | unit | max. value)
0
4294967295
Subcodes
Info
C00161/1
Status determining error (32-bit)
Read access Write access CINH PLC STOP No transfer COM MOT