I/O terminals

6.1

Digital terminals

184

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Short overview of the parameters for the digital terminals:

Tip!
For debouncing digital inputs, two parameterisable delay elements (

L_GP_DigitalDelay1

and

L_GP_DigitalDelay2

) are available.

Application example: Debouncing a digital input

( 468)

Related topics:

User-defined terminal assignment

( 191)

Electrical data

( 197)

Parameter

Info

Lenze setting

Value Unit

C00115/1

(from version 02.00.00)

Function assignment of DI1 and DI2

Configuring DI1 and DI2 as frequency inputs

0: DI1=In1 / DI2=In2

Digital inputs DI1 ... DI5

C00114

DIx: Polarity

Bit coded

C00443/1

DIx: Terminal level

-

C00443/2

DIx: Output level (to the application)

-

Digital output DO1 / relay output

C00118

DOx: Inversion

Bit coded

C00444/1

DOx: Input level (from the application)

-

C00444/2

DOx: Terminal level

-

Digital outputs - terminal configuration

C00621/1

LS_DigitalOutput:bRelay

1001: LA_nCtrl_bDriveFail

C00621/2

LS_DigitalOutput:bOut1

1000: LA_nCtrl_bDriveReady