C00007
Parameter | Name:
C00007 | Control mode
Data type: UNSIGNED_16
Index: 24568
d
= 5FF8
h
Selection of how the application is to be controlled.
Selection list
(Lenze setting printed in bold)
Info
0 Wiring has changed
This display appears when the preset configuration has
been reparameterised via the connection parameters.
9 Local mode
The technology application is controlled via the control
elements at the 8400 motec.
Detailed information on this control mode can be found
in the mounting instructions/hardware manual.
The digital input terminals in local mode are assigned as
follows:
• DI1 = setpoint of P2/fixed setpoint 3
• DI2 = fixed setpoint 2/3
• DI3 = activate DC injection brake
• DI4 = change of direction of rotation
• If the reversal of rotation direction is permanently
set to ccw (left) (DIP1/2 = "ON") via DIP switches,
DI4 has no influence.
• DI5 = manual release of holding brake (set operating
mode in
10 Terminals 0: Jog1; Jog2; DCB; R/L
The technology application is controlled via the digital
input terminals of the controller:
• DI1 = fixed setpoint 1/3
• DI2 = fixed setpoint 2/3
• DI3 = activate DC injection brake
• DI4 = change of direction of rotation
• DI5 = manual release of holding brake (set operating
mode in
12 Terminals 2: Jog1; Jog2; QSp; R/L
The technology application is controlled via the digital
input terminals of the controller:
• DI1 = fixed setpoint 1/3
• DI2 = fixed setpoint 2/3
• DI3 = quick stop
• DI4 = change of direction of rotation
• DI5 = open/close holding brake (in conjunction with
)
14 Terminals 11: R/L; DCB; MPotUp;
MPotDown
The technology application is controlled via the digital
input terminals of the controller:
• DI1 = change of direction of rotation
• DI2 = activate DC injection brake
• DI3 = motor potentiometer: Higher speed
• DI4 = motor potentiometer: Lower speed
• DI5 = manual release of holding brake (set operating
mode in
16 Terminals 16: Jog1; Jog2; R/QSP; L/
QSP
The technology application is controlled via the digital
input terminals of the controller:
• DI1 = fixed setpoint 1/3
• DI2 = fixed setpoint 2/3
• DI3 = CW rotation/quick stop
• DI4 = CCW rotation/quick stop
• DI5 = manual release of holding brake (set operating
mode in
40 Network (MCI/CAN)
The technology application is controlled via fieldbus
communication (depending on the available
communication unit).