beautypg.com

3 l_pctrl_1, L_pctrl_1, Block – Lenze 8400 motec User Manual

Page 450: Reset the entire pid contro, Bena, 12 function library

background image

12

Function library

12.3

L_PCTRL_1

450

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

12.3

L_PCTRL_1

This FB is a PID controller and can be used for various control tasks (e.g. as dancer position controller,

tension controller, or pressure controller).
The FB is provided with the following functions:

• Adjustable control algorithm (P, PI, PID)
• Ramp function generator for preventing setpoint step-changes at the input
• Limitation of the controller output
• Factorisation of the output signal
• Vp adaptation
• Integral action component can be switched off

Inputs

Identifier

Data type

Information/possible settings

nAdapt_a

INT

Adaptation of gain Vp set in

C00222

in percent

• Internal limitation to ± 199.9 %

• Changes can be done online.

• Display parameter:

C00830/7

nNset_a

INT

Speed setpoint

• Scaling: 16384 ≡ 100 %

• Internal limitation to ± 199.9 %

• Display parameter:

C00830/10

nSet_a

INT

Sensor and process setpoint for operating modes 2, 4 and 5

• Scaling: 16384 ≡ 100 %

• Internal limitation to ± 199.9 %

• Display parameter:

C00830/8

E$FW(T6HW

E,2II

Q$FWBD

E(QDEOH,QIOXHQFH5DPS

Q,QIOXBD

Q2XWBD

Q16HWBD

Q6HWBD

Q$GDSWBD

&

&

&

&

&

&

&

&

7Q

&

9S

&

.G

___

_

_

___

&

___

_

&

Q3,'2XWBD

/B3&75/B

&

&

&

&

&

&

&

&

&

&

E,Q$FW

&

E3,'2II

&

Q3,'2XWBD

Q,QIOXHQFH2XWBD