C02580 | holding brake: operating mode, C02581 | holding brake: speed thresholds, C02580 – Lenze 8400 motec User Manual
Page 422: C02581/1, C02581/2, C02581/3, Ation, 11 parameter reference
![background image](/manuals/566305/422/background.png)
11
Parameter reference
11.2
Parameter list | C02580
422
Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02580
C02581
Parameter | Name:
C02580 | Holding brake: Operating mode
Data type: UNSIGNED_8
Index: 21995
d
= 55EB
h
Selection of the operating mode for holding brake control
Selection list
(Lenze setting printed in bold)
Info
0 Brake control off
No holding brake is used. Internal control is switched off.
11 Manually controlled
The holding brake is released and applied via the
bBrkRelease application input.
• In the Lenze setting, bBrkRelease is linked with the
digital input DI5 if control takes place via terminals.
12 Autom. controlled
The holding brake is automatically released and closed
via speed setpoint comparisons.
13 Semi-automat. controlled
From version 02.00.00
The holding brake is released and applied via the
bBrkRelease application input.
• In the Lenze setting, bBrkRelease is linked with the
digital input DI5 if control takes place via terminals.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C02581 | Holding brake: Speed thresholds
Data type: INTEGER_16
Index: 21994
d
= 55EA
h
Speed setpoint threshold and hysteresis for automatic holding brake control
Setting range
(min. value | unit | max. value)
0.00
%
199.99
Subcodes
Lenze setting
Info
C02581/1
5.00 %
Holding brake: Switching threshold
• Switching threshold of the speed setpoint from which
on the holding brake is released/applied
automatically.
C02581/2
1.00 %
Holding brake: Hyst.release
• Hysteresis for holding brake release.
• Release threshold = switching threshold + release
hysteresis
C02581/3
1.00 %
Holding brake: Hyst. close
• Hysteresis for holding brake application.
• Application threshold = switching threshold -
application hysteresis
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100