Motor temperature monitoring (PTC)

For detecting and monitoring of the motor temperature, a PTC thermistor (DIN 44081/DIN 44082)

or a thermal contact (NC contact) can be connected to the terminals T1 and T2.

• If 1.6 kΩ < R < 4 kΩ at the terminals T1 and T2, the monitoring will respond, see functional test

below.

• If the monitoring responds:

• The error response set in

C00585

is activated (Lenze setting: "Fault").

• The "

OH3: Motor temperature (X106) triggered

" error message is entered into the Logbook.

• A setting of

C00585

= "0: No Reaction" deactivates the monitoring.

Tip!
We recommend to always activate the PTC input when using motors which are equipped

with PTC thermistors or thermostats. This prevents the motor from being destroyed by

overheating.

Functional test
Connect a fixed resistor to the PTC input:

• R > 4 kΩ : Fault message must be activated.
• R < 1 kΩ : Fault message must not be activated.

Stop!

• The controller can only evaluate one PTC thermistor!

Do not connect several PTC thermistors in series or parallel.

• To achieve full motor protection, an additional temperature monitoring with separate

evaluation must be installed.

Note!

• In the Lenze setting (

C00585

= "1: Fault"), motor temperature monitoring is activated!

• Lenze three-phase AC motors are provided with a thermal contact on delivery.