1 safety instructions with regard to commissioning, Safety instructions with regard to commissioning, 3commissioning – Lenze 8400 motec User Manual

Page 31

background image

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

31

3

Commissioning

3.1

Safety instructions with regard to commissioning

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

3.1

Safety instructions with regard to commissioning

General safety instructions
In order to prevent injury to persons or damage to material assets

• check before connecting the mains voltage

• the wiring for completeness, short circuit, and earth fault
• the "emergency stop" function of the entire system
• that the motor circuit configuration (star/delta) is adapted to the output voltage of the

controller

• the in-phase connection of the motor
• The direction of rotation or the encoder (if available)

• check the setting of the most important drive parameters before enabling the controller:

• the V/f rated frequency must be adapted to the motor circuit configuration!
• the drive parameters relevant for your application must be set correctly!
• the configuration of the I/O terminals must be adapted to the wiring!

• ensure that there are no active speed setpoints before enabling the controller.

Safety instructions with regard to motor operation

Danger!

The RFR control input is connected as default with a bridge to +24 V, which means that

the controller is enabled!

• This input can also be used for switching on/off the drive. For this purpose, the bridge

must be replaced by cabling.

Danger!

• For thermal reasons, continuous operation of self-ventilated motors at a low field

frequency and rated motor current is not permissible!

• In the Lenze setting, the

Motor temperature monitoring (PTC)

is activated.

( 176)

• In the Lenze setting, the

Brake resistor monitoring (I2xt)

is activated. The activation of

the monitoring function causes a switch-off of the braking operation.

( 177)

• With regard to the setting of the V/f base frequency (

C00015

), observe the following

difference to the controllers 8400 StateLine/HighLine/TopLine:

In case of the 8400 motec, the reference voltage for the V/ base frequency is the rated

motor voltage (

C00090

) according to the motor nameplate (independent of the

supply voltage).