C00071 | ti speed controller, C00073 | vp imax controller, C00074 | ti imax controller – Lenze 8400 motec User Manual
Page 345: C00075 | vp current controller, C00075, C00071/3, C00073, C00074, Reset time ti, 11 parameter reference

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
345
11
Parameter reference
11.2
Parameter list | C00071
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00071
C00073
C00074
C00075
Parameter | Name:
C00071 | Ti speed controller
Data type: UNSIGNED_16
Index: 24504
d
= 5FB8
h
From version 03.00.00
Reset time Ti of the speed controller for sensorless control for synchronous motors (
Setting range
(min. value | unit | max. value)
0.0
ms
6000.0
Subcodes
Lenze setting
Info
C00071/1
0.0 ms
Reserved
C00071/2
0.0 ms
Reserved
C00071/3
100.0 ms
: Ti speed controller
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10
Parameter | Name:
C00073 | Vp Imax controller
Data type: UNSIGNED_16
Index: 24502
d
= 5FB6
h
Amplification factor Vp for Imax controller
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
16.00 0.25
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00074 | Ti Imax controller
Data type: UNSIGNED_16
Index: 24501
d
= 5FB5
h
Reset time Ti for Imax controller
Setting range
(min. value | unit | max. value)
Lenze setting
12
ms
9990 65 ms
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00075 | Vp current controller
Data type: UNSIGNED_16
Index: 24500
d
= 5FB4
h
From version 03.00.00
Gain factor Vp of the current controller for certain inverter functions (parameter identification, flying restart circuit)
• After the motor to be used has been selected from the motor catalogue, the suitable value can be entered
automatically.
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
V/A
500.00 7.00 V/A
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100