12 function library – Lenze 8400 motec User Manual
Page 452

12
Function library
12.3
L_PCTRL_1
452
Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Parameter
Parameter
Possible settings
Info
0.1
500.0 Gain Vp
• Lenze setting: 1.0
20
ms
6000 Reset time Tn
• Lenze setting: 400 ms
0.0
5.0 Differential component Kd
• Lenze setting: 0.0
-199.9
%
+199.9 Maximum value of the PID operating
range
• Lenze setting: 199.9 %
-199.9
%
+199.9 Minimum value of the PID operating
range
• Lenze setting: -199.9 %
0.0
s
999.9 Acceleration time for the ramp at the
PID output (should be set as steep as
possible)
• Lenze setting: 0.1 s
0.0
s
999.9 Deceleration time for the ramp at the
PID output
• Lenze setting: 0.1 s
(Pos. Maximum)
(Pos. Minimum)
(Neg. Minimum)
(Neg. Maximum)
0.0
%
199.9 Operating range
• Determination of the operating
range for the PID process
controller by limiting the input
signal nSet_a.
• Lenze setting: No limitation (-
199.9 % ... +199.9 %)
(from version 04.00.00)
Root function
• Lenze setting: "0: Off"
0
Off
The actual value at nAct_a is not
changed for further processing.
1
On
The square root of the actual value at
nAct_a is taken for further
processing.