C00567 | resp. to speed controller limited, C00572 | brake resistor overload threshold, C00574 | resp. to brake resist. overtemp – Lenze 8400 motec User Manual
Page 383: C00579 | resp. to speed monitoring, C00574, Serves, C00572, Setting, Se in, C00579
Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
383
11
Parameter reference
11.2
Parameter list | C00567
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00567
C00572
C00574
C00579
Parameter | Name:
C00567 | Resp. to speed controller limited
Data type: UNSIGNED_8
Index: 24008
d
= 5DC8
h
From version 02.00.00
Response if speed controller output is limited (bLimSpeedCtrlOut = TRUE)
Selection list
(Lenze setting printed in bold)
0 No Reaction
1 Fault
4 WarningLocked
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00572 | Brake resistor overload threshold
Data type: UNSIGNED_8
Index: 24003
d
= 5DC3
h
Adjustable threshold for monitoring the brake resistor utilisation
• The response for reaching the threshold can be selected in
Setting range
(min. value | unit | max. value)
Lenze setting
0
%
100 100 %
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00574 | Resp. to brake resist. overtemp.
Data type: UNSIGNED_8
Index: 24001
d
= 5DC1
h
Response which is triggered if the threshold set in
for monitoring brake resistor utilisation is reached.
Selection list
(Lenze setting printed in bold)
0 No Reaction
1 Fault
4 WarningLocked
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00579 | Resp. to speed monitoring
Data type: UNSIGNED_8
Index: 23996
d
= 5DBC
h
Response when the max. speed limit (
) or output frequency limit (
Selection list
(Lenze setting printed in bold)
0 No Reaction
1 Fault
4 WarningLocked
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1