Storage ASIC
The status of the storage ASIC in the CRU.
Values: Initialized, Not Initialized, Unknown
Initialization State
Actions
Replace
Launches the Replace SNDA guided procedure, which provides step-by-step instructions for replacing
the ServerNet/DA CRU.
Storage ASIC Initialization Test
Prompts the storage subsystem manager process ($ZZSTO) to initialize the storage ASIC in the
CRU. If initialization fails, an alarm is generated.
This action is triggered automatically when a new CRU is inserted while OSM is running or when
an SCF STATUS ADAPTER command is issued. If a CRU is inserted while OSM is not running,
perform this action after logging on to the OSM Service Connection.
Test Verify
Performs basic tests on the CRU. You can perform this action when the CRU is online.
SSAC (SCSI SAC)
The SCSI SAC (ServerNet addressable controller) is a SCSI plug-in card mounted on these devices:
•
I/O multifunction (
) 2 CRU (external SCSI controller, SAC 3)
•
CRU (There can be up to four SCSI SACs on each ServerNet/DA CRU.)
SCSI SACs are used for connecting external SCSI devices such as tape drives.
Location in OSM Tree: System > Group > Module > IOMF2 > SSAC
Example: SSAC (1.1.50.3)
Attributes
SSAC
Displayed in the Attributes tab and Attributes dialog box only if the value is
something other than OK.
Service State
Physical
The type of CRU this SAC is connected to.
values: SSAC, FSAC, SCSI
Type
The part number of the component that was assigned in manufacturing. Use
part numbers for identifying and ordering parts.
Part Number
A unique serial number that identifies the component. Track IDs are used for
tracking components.
Track ID
A code that identifies the generation of the component. Hardware revision
codes are used for tracking components.
Hardware Revision