Actions, Abort, Dump – HP Integrity NonStop J-Series User Manual

Page 159: Firmware update, Responsive test, Start, Stop, Test verify, Gesa (gigabyte ethernet servernet adapter), Attributes

background image

Actions

Abort

Terminates operation of the G4SA ServerNet addressable controller. When the Abort action
finishes, the SAC is in the Stopped state.

Dump

Copies a memory image from a G4SA SAC to a file on the local system. The file will be the last
(highest numbered) file of the chain started with the file specified in the

Dump File Name

attribute

of the SAC.

CAUTION:

The SAC and PIFs will be unavailable while the SAC is being dumped.

Firmware Update

Updates the boot firmware for the G4SA SAC.

Responsive Test

Runs an online test that verifies the SAC is integrated with the LAN subsystem, is owned, and is in
the Started state.

Start

Loads the controller operational code and starts the ServerNet addressable controller. The SAC
must be in the Stopped state before you perform this action. When the Start action completes, the
SAC is in the Started state.

Stop

Rather than automatically stopping the G4SA SAC (as the Abort action does), this action first warns
you if the SAC is currently in use (and stops it only after you confirm).

Test Verify

Runs the power-on self-test for the SAC.

GESA (Gigabyte Ethernet ServerNet Adapter)

An adapter that connects the ServerNet connections inside a server to an Ethernet local area
network (LAN). The Gigabit Ethernet ServerNet adapter is similar to the Fast Ethernet ServerNet
adapter but offers enhanced performance.

The Gigabit Ethernet ServerNet Adapter (GESA) CRU contains one Gigabit Ethernet ServerNet
addressable controller (

SAC

), which contains one Ethernet physical interface (

PIF

), resulting in one

Ethernet port on each GESA CRU.

Location in OSM Tree: System > Group > Module > GESA

Slot Location: GESA CRUs can be located in slots 51, 52, 53, and 54 in IOMF2 enclosures (service
side).

Example: GESA $ZZLAN.GESA0 (1.1.53)

Attributes

GESA

Displayed in the Attributes tab and Attributes dialog box only if the value is
something other than OK.

Values

Service State

GESA (Gigabyte Ethernet ServerNet Adapter)

159