beautypg.com

Configure power source as ups, Delete the power source configuration, Replace – HP Integrity NonStop J-Series User Manual

Page 195: Set led state, Power supply (sas disk enclosure), Attributes, Actions, Power supply and fan (telco sas disk enclosure), Attributes actions, Sas power supply and fan

background image

Configure Power Source as UPS

Sets the Power Source attribute value for this power supply unit to UPS. You must be logged on as
super.super to perform this action. Upon initiating the action, you are prompted to enter the IPv4
address of the UPS.

For Integrity NonStop NS16000 series servers, you must use this action to configure at least one
of your processor switch power supplies (to specify UPS as the backup power source) in order for
OSM to provide an orderly system shutdown in the event that a power failure exceeds the
powerfail-delay time interval specified for your UPS. For more information on preparing for AC
power-fail scenarios, see the NonStop NS16000 Series Planning Guide. For more information on
using the POWERFAIL_DELAY_TIME command to specify the Power-Failure-to-Shutdown time interval,
see the SCF Reference Manual for the Kernel Subsystem.

Delete the Power Source Configuration

Sets the Configuration > Power Supply attribute value to Not Configured. You must be logged on
as super.super to perform this action.

Replace

Launches the guided procedure to replace a processor switch power supply.

Set LED State

Turns on or off the amber LED located on the PIC port. The current state is indicated by the

LED

State

attribute.

Power Supply (SAS Disk Enclosure)

A subcomponent of a

SAS Disk Enclosure

.

System > SAS Disk Enclosures > SAS Disk Enclosure > Power Supply

Attributes

None.

Actions

Replace

Launches a documented service procedure to replace a power supply in a SAS disk enclosure.

Power Supply and Fan (Telco SAS Disk Enclosure)

In the OSM Service Connection, a subcomponent displayed for a Telco

SAS Disk Enclosure

only.

In commercial SAS Disk Enclosures,

SAS Power Supplies

and

SAS Fans

are represented by separate

objects in OSM.

System > SAS Disk Enclosures > SAS Disk Enclosure > Power Supply and Fan

Attributes

None.

Actions

Replace

Launches a documented service procedure to replace a power supply or fan in a Telco SAS disk
enclosure.

Power Supply (SAS Disk Enclosure) 195

This manual is related to the following products: