beautypg.com

Actions, Blink all leds off, Blink all leds on – HP Integrity NonStop J-Series User Manual

Page 146: Disable all drive bypass, Enable all drive bypass, Replace, Set physical location, Verify path a access, Verify path b access, Fcdm collection

background image

Actions

Blink All LEDs Off

Turns off the blinking of the fault LEDs on the FCDM, disks, FC-AL I/O module, power supplies,
and fans.

Blink All LEDs On

Causes the fault LEDs on the FCDM, disks, FC-AL I/O module, power supplies, and fans to blink.

Disable All Drive Bypass

Opens up the specified port or ports (A and/or B) on all disk drives in the FCDM for use.

Enable All Drive Bypass

Shuts down the specified port or ports (A and/or B) on all disk drives in the FCDM.

Replace

Displays the procedure for replacing the FCDM.

Set Physical Location

Allows you to assign these

Physical Location

attributes for the FCDM:

Rack Name is a user-defined name for the rack containing the FCDM. You can enter up to
15 alphanumeric characters.

Rack Offset is a numerical value representing the location of the FCDM within the rack. A
valid integer (from 1 to 42) must be specified when performing the Set Physical Location
action, or the action fails.

Locator is an optional text string to help identify the physical location of the FCDM. It must
contain alphanumeric characters only.

This parameter, used for DC-powered Telco systems only, allows you to specify a system alarm
panel (SAP) identifier, which is then displayed in OSM by the Alarm Panel Identifier attribute
for this hardware resource. An system alarm panel (SAP) provides visual alarm indicators and
relays for generating three levels of alarms to alert the customer to the severity of a hardware
error in the system. By default, systems are configured with one SAP located in the CIA for
the group 11 I/O enclosure. You might need to set the Alarm Panel Identifier if the system
has multiple SAPs, you add equipment to a system, or you move equipment from one system
to another.

With T0682 H02 AAN and later, you can also use the

Physical Configuration Tool

to set the Rack

Name and Rack Offset values in a consistent manner throughout the system while you create a
physical view of your modular racks.

Verify Path A Access

Verifies that Path A from the FCDM via FC-AL I/O module A to the FCSA FSAC is responding.

Verify Path B Access

Verifies that Path B from the FCDM via FC-AL I/O module B to the FCSA FSAC is responding.

FCDM Collection

The OSM Service Connection displays all

Fibre Channel disk modules (FCDMs)

within FCDM

Collection objects, whether or not they are daisy-chained. FCDMs that are daisy-chained together
(up to four) are displayed within the same FCDM Collection object. If an FCDM Collection object

146

System Resources

This manual is related to the following products: