beautypg.com

Restore clim configuration, Restore default storage path configuration, Rom update – HP Integrity NonStop J-Series User Manual

Page 108: Show clim/key manager registration information, Start, Stop, Stop storage paths, Switch storage paths away, Clims, Attributes

background image

object, although CLIM subcomponents, such as the Hard Disk object will not be displayed by OSM
if SNMP is not available.

Restore CLIM Configuration

Restores the CLIM configuration from a previously saved file at a user-specified or default location.

Restore Default Storage Path Configuration

Valid for Storage CLIM only. OSM issues a SPI command to the storage subsystem to restore the
active paths of all storage devices using the CLIM to their default configurations.

ROM Update

Updates the ROM firmware. Upon completion, OSM offers to reboot the CLIM, in order for the
CLIM to start using the updated firmware.

Show CLIM/Key Manager Registration Information

This action, applicable only for CLIMs that have been registered through the

Register CLIMs with

Key Managers

guided procedure, displays information concerning the registration of the CLIM

with the Key Manager or Key Manager Cluster, including:

Key Manager Cluster configuration, including tier assignment and IP addresses.

Local CA certificate that signed the Server certificate.

Client Certificate information.

CLIM/Key Manager user name.

Start

OSM issues a SPI command to CIPMAN equivalent to SCF START CLIM.

Stop

Encompasses both the SCF STOP and ABORT commands. OSM issues a SPI command to CIPMAN
equivalent to SCF STOP CLIM. If this fails because there are open sockets and you tell OSM to
proceed any way, OSM issues a SPI command to CIPMAN equivalent to SCF ABORT CLIM,
FORCED.

Stop Storage Paths

Valid for Storage CLIM only. Stops all storage paths from the CLIM.

Switch Storage Paths Away

Valid for Storage CLIM only. OSM issues a SPI command to the storage subsystem to switch the
active paths of all storage devices using the CLIM away from the CLIM.

CLIMs

In the OSM Service Connection, CLIMs is a collection object that contains all

CLIM

(CLuster I/O

Module) devices configured on a NonStop BladeSystem or supported NonStop NS-series system.

Location in OSM Tree: System > CLIMs

Attributes

None.

108 System Resources