Infiniband hca card, Logical, Processor boot millicode firmware – HP Integrity NonStop J-Series User Manual
Page 219: Actions, Reset, Responsive test, Sp firmware update, Smart array controller (clim), Attributes, Smart array controller

Processor Boot Millicode Firmware
These attributes are displayed only for SPs located in PMF or PMF2 CRUs; not for those in IOMF
or IOMF2 CRUs.
The version of the firmware on the processor on the same PMF CRU with this
service processor.
Version
The name of the file to be used for the Processor Boot Millicode firmware
update. (CPUCODE9)
Default File Name
The version of the firmware to be used for the Processor Boot Millicode
firmware update.
Default File Version
The differences, if any, between the current and default firmware versions.
Compare State
Actions
Reset
Causes the service processor (SP) to reload the service processor operating image from the FLASH
PROM.
If the CLCI and CNSL (console) sessions are running through an SP that is reset, the session windows
stop responding, and you must switch to the other paired SP by specifying the appropriate IP
addresses.
When you reset a master service processor (MSP), any LAN client connections to that MSP are
terminated and must be reconnected by the client.
Responsive Test
Verifies that the component is connected and responding.
SP Firmware Update
Updates the firmware for a single service processor (SP).
Optional Parameter: File Name -- the name of the firmware file.
Syntax: $volume.subvolume
Default value: $SYSTEM.SYSnn
Smart Array Controller (CLIM)
A subcomponent of G6 and Gen8
.
Location in OSM Tree: System > CLIMs > CLIM > Smart Array Controller
Attributes
Smart Array Controller
Displayed in the Attributes tab and Attributes dialog box only if the value is
something other than OK.
Service State
Logical
The state of the Smart Array Controller as known to the operating system on
the server. Possible values include: OK and Fault.
Device State
Smart Array Controller (CLIM)
219