Power Supply (VIO)

Provides power to the VIO enclosure (represented in the OSM Service Connection as a

VIO module

).

There are two VIO power supplies in each VIO enclosure.

Attributes

VIO Power Supply

Displayed in the Attributes tab and Attributes dialog box only if the value is
something other than OK.

Values

Service State

Physical

Identifies the manufacturer of the component.
Displayed for VIO power supplies in S-series VIO modules only.

Manufacturer

The part number of the component that was assigned in manufacturing. Use
part numbers for identifying and ordering parts.

Part Number

Logical

The state of the component as known to the operating system on the server.

Values

Device State

Configuration

NOTE:

These attributes are not displayed for a power supply unit in an S-series VIO Module.

Indicates the state of this power supply's backup power configuration as
known to OSM.
Values: Not Configured, AC, UPS, Unknown

You must use the

Configure Power Source as UPS

action to set this value to

UPS in order for OSM to provide an orderly system shutdown in the event
that a power failure exceeds the powerfail-delay time interval specified for
your rack-integrated UPS.

Power Source

The IPv4 address of the UPS configured to provide backup power in the event
of a power failure, if specified through the

Configure Power Source as UPS

action.

UPS IPv4 Address

Actions

Configure Power Source as AC

Sets the Configuration > Power Supply attribute value for this power supply to AC. You must be
logged on as super.super to perform this action.

NOTE:

This action is not valid for a power supply unit in an S-series VIO Module.

Configure Power Source as UPS

Sets the Power Source attribute value for this power supply to UPS. You must be logged on as
super.super to perform this action. Upon initiating the action, you are prompted to enter the IPv4
address of the UPS.

You must use this action to configure at least one of your VIO power supplies (to specify UPS as
the backup power source) in order for OSM to provide an orderly system shutdown in the event

196

System Resources