The version of storage software running on the CLIM.

Storage Software Version

Indicates whether or not the CLIM has exceeded its temperature threshold
for proper operation. The possible values are “Temperature sensing not
supported by this system,“ “Normal”, “Degraded,” and “Critical.” If the
value is not available, this attribute is not displayed.

Temperature Status

List of physical Ethernet interfaces on the CLIM that are operational.

Up Physical Network Interfaces

The connectivity status of the CLIM to the ServerNet X fabric. Displayed for
both X1 and X2 fabrics, provided the CLIM is configured for two connections
per ServerNet fabric. Possible values include:

Correctly Connected: The CLIM is correctly connected to the ServerNet X
fabric.

Not Connected: The CLIM is not connected to the ServerNet X fabric.

Location Mismatch: The CLIM is configured to be connected to a p-switch,
but is connected to a different port.

System Name Mismatch: The CLIM is configured with a system name that
does not match the name of the system to which it is connected.

Operation Mode Mismatch: The operation mode does not match with the
configured operation mode.

Number of Connections per ServerNet Fabric Mismatch: The number of
connections per ServerNet fabric does not match with the configured
number.

Port Not Configured for CLIM: The p-switch is not configured to be
connected to a CLIM.

Unsupported Location: the configured location is not supported for
connection with a CLIM.

Unknown: The system is unable to determine the connection state of the
CLIM on this fabric.

X1 Fabric Connection State
X2 Fabric Connection State

The connectivity status of the CLIM to the ServerNet Y fabric. Displayed for
both Y1 and Y2 fabrics, provided the CLIM is configured for two connections
per ServerNet fabric. Possible values include:

Correctly Connected: The CLIM is correctly connected to the ServerNet Y
fabric.

Not Connected: The CLIM is not connected to the ServerNet Y fabric.

Location Mismatch: The CLIM is configured to be connected to a p-switch,
but is connected to a different port.

System Name Mismatch: The CLIM is configured with a system name that
does not match the name of the system to which it is connected.

Operation Mode Mismatch: The operation mode does not match with the
configured operation mode.

Number of Connections per ServerNet Fabric Mismatch: The number of
connections per ServerNet fabric does not match with the configured
number.

Port Not Configured for CLIM: The p-switch is not configured to be
connected to a CLIM.

Unsupported Location: the configured location is not supported for
connection with a CLIM.

Unknown: The system is unable to determine the connection state of the
CLIM on this fabric.

Y1 Fabric Connection State
Y2 Fabric Connection State

The DNS name of the Integrated Lights Out (iLO) on the CLIM.

iLO DNS Name

The IPv4 address of the Integrated Lights Out (iLO) port on the CLIM. The IP
address of the CLIM iLO is displayed only when SNMP is available; however,
the iLO DNS Name attribute is displayed even when SNMP is not available.

iLO IPv4 Address

Possible values: Up or Down.

iLO Pulse Link State