MicroLogix 1000 and PLC-500 A.I. Series Software Reference
20-10
4.
To add additional rights to the user, press
[Ins]
. The system displays the list of
remaining rights (in the case of a new user, the only remaining right is Data Table
Value Modification). Press
[Enter]
to add this right (or
[Esc]
to back out without
adding this right). The system adds the Data Table Value Modification right and
displays the Data Table Access Control List.
Use the Data Table Access Control List to designate addresses that you do or do
not want the user to be able to modify while online.
§
Press
[F1]
to toggle the mode between displaying addresses the user
can
modify and addresses the user
cannot
modify. (This allows you to choose to
enter the smaller of the two lists.)
§
Press
[Ins]
to add a range of addresses into the Data Table Access List. The
system prompts you for the low address in the range. Type the address and
press
[Enter]
. The system asks you for the high address in the range. Type
the address and press
[Enter]
. Repeat this procedure for as many address
ranges as you like. If set to “CANNOT,” and you leave the list blank, the user
will have access to
all
Data Table addresses.
§
Use the arrow keys to highlight an address and press
[Del]
to remove the
address from the list.
§
Press
[Esc]
to end editing and save the list.
5.
To delete a right from the user, use the up and down arrow keys to select a right to
delete, and press
[Del]
. The right disappears from the list.