MicroLogix 1000 and PLC-500 A.I. Series Software Reference
6-30
This screen has four columns. You can edit two of them:
Fixup
and
Type
.
§
Address
: The original address from the library file
§
Fixup
: The address that will be used when importing the library
§
Type
: The address type. There are three types of addresses:
§
Base addresses, which act as anchors for relative addresses. When you
change a base address, the relative addresses that follow it (up to the next
base address) change similarly.
§
Relative addresses, whose addresses depend on base addresses
§
Global addresses, which are independent of base addresses
§
Symbol
: The symbol assigned to the address in the current project database.
2.
To toggle the addressing type between base, global, and relative:
§
Highlight the entry in the Type column for the address you want to change.
§
Keep pressing
[Enter]
until the type you want is displayed. For instance, if
T4:0 is a base address, and you want to toggle it to global, move the highlight
bar to the word
Base
next to address T4:0, and press
[Enter]
.
3.
To edit an address:
§
Cursor to the address in the Fixup column that you want to offset.
§
Press
[Enter]
. An input bar opens at the bottom of the screen, allowing you to
type in a new address.