beautypg.com

Ktx/ktxd interface card, 1784-ktx/ktxd interface card – Rockwell Automation 9323-S5500D A.I. SERIES MICROLOGIX 1000 AND PLC-500 SOFTW User Manual

Page 352

background image

MicroLogix 1000 and PLC-500 A.I. Series Software Reference

15-16

1784-KTX/KTXD Interface Card

The table below describes the parameters that become available when you select this

device.

Communication Medium

Parameter

DH-485

DH+ / DH-485 Bridged

DH+

[F1]

Computer/

Terminal
Address

enter the station address
(0-31 decimal). This
address must be unique
on the network.

enter the station address
(0-77 octal). This
address must be unique
on the network.

enter the station address (0-77
octal). This address must be
unique on the network.

[F4]

KTX

Communica-
tions Board
Addr

Hexadecimal address
must match the KTX
card’s base memory
address.*

Hexadecimal address
must match the KTX
card’s base memory
address.*

Hexadecimal address must
match the KTX card’s base
memory address.*

[F5]

Baud rate

select the baud rate of
the DH-485 network

not available

not available

[F7]

1785-KA5

DH+ Address

not available

enter the DH+ station
address of the 1785-KA5

not available

[F8]

Terminal

Name

not available

enter an 8-character
name that will be
displayed when a DH+
Who Active is run

enter an 8-character name that
will be displayed when a DH+
Who Active is run

[F9]

DH+ Link

ID

not available

enter the DH+ channel
link ID of the 1785-KA5

not available

[F9]

LOCAL

not available

not available

displays the Configure Local
Remote Settings menu. From
this menu, press

[F1]

Network

Mode

to toggle between LOCAL,

REMOTE, or DH+ ROUTING.
Refer to

DH+ Direct

Local/Remote Settings

on page

15-29

.

*For information on excluding memory addresses to avoid conflicts with the interface

card, refer to the

Hardware Interface Configuration Guide

.

This manual is related to the following products: