MicroLogix 1000 and PLC-500 A.I. Series Software Reference
11-24
[F7]
Group Bits into word
Instead of listing each bit address separately on the Xref Report, they are included
in the cross references for the word address. This compressed format is the same
as the compressed mode for cross reference data printed on the ladder diagram (see
page
11-19
), except for grouping the bit cross references in with the word cross
references. Two examples are shown below.
B3:0 - {12},1,5,[3]1,3,{15},[2]/1,2,/5,6,[3]/1,/3
B3/12 - 1,5,[3]1,3
B3/15 - /1,2,/5,6,[3]/1,/3
Compressed with
Group Bits into word
enabled
Compressed
T4:19 - {ACC/05},/1
T4:19.ACC/5 - /1
Compressed
Compressed with
Group Bits into word
enabled
To enable the Group Bits Into Word option, you must set the Xref Sort Mode to
Address, the Xref Mode to Compressed, and disable description and symbols.
[F8]
Margin between xrefs
Enter the number of lines (from 0-3) to leave blank between addresses.
Clear All Xref Disable Flags
When an address occurs repeatedly within a program, printing its cross reference data
may become overwhelming. For instance, an output used as a storage bit may have
many cross references. You may choose to enter a xref disable flag with the database
editor, disabling the printout of cross reference data on the ladder report and search
displays for that output. (See
Chapter 9 - Using the Database Editor
.)