Program note editor – Rockwell Automation 9323-S5500D A.I. SERIES MICROLOGIX 1000 AND PLC-500 SOFTW User Manual
Page 189

Adding Descriptive Text to Ladder Logic
8-19
Program Note Editor
PLC-500 A.I. contains a built-in text editor utility. Use this utility for taking notes
about program development, operations, or for anything you want to remember.
To run the note editor:
1.
Press
[F4]
Tags
. The function keys on the bottom of the screen change to show the
Tags options.
2.
Press
[F7]
Notedit
. The note editor screen appears.
3.
Type the note text. The note editor operates much like a basic word processor,
supporting word wrap and cut/paste features. The following keys are available.
To…
Press…
write the defined block of text to disk
[F1]
mark the start of a block of text. Use the cursor (arrow) keys
to extend the highlighting for the block of text.
[F5]
read a block of text from disk
[F9]
delete the current character or cuts a marked block of text and
saves it to the scrap buffer
[Del]
insert text from the scrap buffer at the current cursor position
[Ins]
Command Portal keys
for this function:
.TN
Shortcut keys for this
function:
[Alt-E]