40 configure threshold of the alarm temperature – CANOGA PERKINS 9175 Command Reference User Manual
Page 698
CanogaOS Command Reference
40-27
Current NTP I/O statistics:
============================================================
time since reset: 175834
receive buffers: 10
free receive buffers: 9
used receive buffers: 0
low water refills: 1
dropped packets: 0
ignored packets: 0
received packets: 32
packets sent: 31
packets not sent: 0
interrupts handled: 32
received by int: 32
Related Commands
show ntp association
show ntp status
40.40 configure threshold of the alarm temperature
To configure the threshold of alarm temperature for system, use the temperature LOW HIGH CRIT
command in Global configuration mode, to return the default threshold, use the no temperature
comomand.
Command Syntax
temperature LOW HIGH CRIT
Command Mode
Global configuration
Usage
When the system temperature is higher than HIGH threshold or lower than LOW threshold, the system
will notify the user by alarm log and buzzer, if the system temperature is higher than CRIT threshold, the
system will automatically shut down the system power. The unit of the threshold is degree Celsius.
For commercial operation device, the threshold range:
LOW [0, 50]; HIGH [50, 90]; CRIT [50, 90];
For industrial operation device, the threshold range:
LOW [-40, 50]; HIGH [50, 105]; CRIT [50, 105];
Examples
The following is sample output from the temperature command:
Switch(config)# temperature 3 78 88
Related Commands