11-3
Usage
Set the timer to emit at least one OAMPDU per second and ensure that the sublayer adheres to the
maximum number of OAMPDUs per second. The minimum is 1 OAMPDU per second and the maximum
is 10 OAMPDU per second
Examples
Switch# configure terminal
Switch (config)# interface eth-0-1
Switch (config-if)# ethernet oam min-rate 1
11.4 ethernet oam max-rate
Use this command to set the OAMPDU maximum number of PDUS per second. Use the no
form of the command to reset max-rate to the default value.
Command Syntax
ethernet oam max-rate PDUS
no ethernet oam max-rate
PDUS The maximum number of PDUs per second in the range <1-10>
Command Mode
Interface mode
Default
The default value of the max-rate is 10 PDUs per second.
Usage
This command is to ensure that the sublayer adheres to the maximum number of
OAMPDUs per second. The minimum is 1 OAMPDU per second and the maximum is 10
OAMPDUs per second.
Examples
Examples
Switch # configure terminal
Switch (config)# interface eth1
Switch (config-if)# ethernet oam max-rate 10
11.5
ethernet oam link-monitor on
Use this command to turn on link monitoring on an interface. Use the no form of this
command to turn link monitoring off.