12 cfm linktrace tests – CANOGA PERKINS 9175 Command Reference User Manual
Page 165
CanogaOS Command Reference
10-8
Usage
1
˅This command is used to transmit a loopback message for a MAC address to a remote MP for fault
verification.
2
˅This command is used to transmit a loopback message to a remote MEP for fault
verification.
Examples
Switch#
loopback ethernet mpid 88 level 7 vlan 30
Switch#
loopback ethernet 8908.0909.1267 level 7 vlan 30 repeat 5 timeout 5
Related Commands
10.12 CFM linktrace tests
Use the procedures in this section to issue CFM path trace messages and to discover the path to a remote
MEP.
Command Syntax
linktrace ethernet MAC (domain DOMAIN | level LEVEL) vlan VLANID
(ttl TTL|)
( timeout TIMEOUT|)
linktrace ethernet mep MEPID (domain DOMAIN | level LEVEL) vlan VLANID
(ttl TTL|)
( timeout TIMEOUT|)
Command Mode
Privileged Exec mode
Default
The default TTL is 64.
The default timeout is 10 seconds.
Usage
1
˅This command is used to transmit a loopback message for a MAC address to a remote
MEP for Path discovery.
2
˅This command is used to transmit a loopback message to a remote MEP for Path
discovery.
Examples
Switch#
linktrace ethernet mep 88 level 7 vlan 30 ttl 64 timeout 5
Switch#