Analog out auxiliary output connector – Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual
Page 97
9
1
26
19
.
11300-I
Section 3A
Primary 9/230 Components
3A-14
Figure 3A.10
Connectors J1, J2, and J3 - 26 Pin Female, D-Shell Connector
Pin No.
Signal
Description
Signal Destination
1
Not Used
2
Not Used
3
CHA_HI
Feedback device Channel A
Servo Module
4
CHB_HI
Feedback device Channel B
Servo Module
5
CHZ_HI
Feedback device Channel Z
Servo Module
6
+5V_ENC
+5V Encoder Power Supply
Feedback Device
7
+5V_ENC
+5V Encoder Power Supply
Feedback Device
8
SEN
Switched +5V Encoder Power Supply (not used)
Feedback Device
9
DRIVE
±
10V analog drive command
Servo Amplifier
10
Not Used
11
Not Used
12
CHA_LO
Feedback device Channel A
Servo Module
13
CHB_LO
Feedback device Channel B
Servo Module
14
CHZ_LO
Feedback device Channel Z
Servo Module
15
Not Used
16
GND
Encoder Power Return
Feedback Device
17
SEN. RET
Encoder Power Return
Feedback Device
18
DRIVE.RET
±
10V analog drive command return
Servo Amplifier
19
Not Used
20
Not Used
21
SHLD_CHA
Shield for phase A
connect at module only
22
SHLD_CHB
Shield for phase B
connect at module only
23
SHLD_CHZ
Shield for phase Z
connect at module only
24
SHLD_+5V
Shield for +5V
connect at module only
25
SHLD_SEN
Shield for switched +5V
connect at module only
26
SHLD_DRV
Shield for drive command
connect at module only
ANALOG OUT Auxiliary Output Connector
An auxiliary analog output is provided through the connector labeled
ANALOG OUT (TB3). This connector is typically used to command an
analog spindle drive system with no position feedback. TB3 is not capable
of receiving encoder feedback information. Figure 3A.11 shows the
location of ANALOG OUT connector. Table 3A.G lists terminal
assignments of this connector.