3a.1.2 reading leds – Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual
Page 88

Section 3A
Primary 9/230 Components
3A-5
Table 3A.B
Connector TB2, TP, Terminal Assignments
Terminal
No.
Signal
Description
Signal Destination
1
+5V
Probe Power
Touch Probe
2
PRB_FIRE
Probe Fired Signal
1
Servo Module
3
TP_GRD
Touch Probe Common
Touch Probe
4
Shield
Probe Shield
connect at module
only
1
The True level (voltage transition the probe fires) is either “HIGH”or “LOW”as defined
by the AMP parameter PROBE TRANSITION.
Refer to the 9/Series CNC 9/230,
9/260, and 9/290 AMP Reference Manual, publication 8520-6.4, for more
information.
Important: The touch probe connector supports only +5V probing device
applications.
The 9/230 can have two LEDs (DS4 is present only if you have purchased
the 9/230 remote I/O option). Figure 3A.1 shows the location of these
LEDs on the main board. Use them to determine the following:
Table 3A.C
LED Sequence at Power Up for the 9/230
LED
Status
Description
DS2
WDOG OK
ON
System is running.
WDOG OK
OFF
Watchdog timeout has occurred, or system did not
power-up properly
DS4
NA COMM
ACTIVE
ON
Active Link to PLC. This is the normal state when the
RIO channel is on and active.
ACTIVE
FLASHING
The remote I/O channel is on and active but the PLC is
currently in program mode.
OFF
Remote I/O channel is offline. The port is not being
used, not configured, or not attached to a remote I/O
scanner device.
3A.1.2
Reading LEDs