Section 15B
Replacement Procedures
15B-5
6.
Press any key when you have connected the control to your personal
computer. After a few minutes the PC displays this screen:
Connection established.
Device is a 9/290 CNC
Downloading required system modules...
Module:Boot Directory Revision 1.0
Status: downloaded
Module:XLINX Data
Revision 1.0
Status: downloaded
Module:Main CPU Exec
Revision 1.0
Status: downloaded
Module:I/O CPU Exec
Revision 1.0
Status: downloading (81%)
If you have a 9/230 or 9/260 a similar screen appears that does not
include the last message about the I/O CPU. Also, the 9/230 downloads
a servo executive. If this screen does not appear, refer to the table at the
end of this section for a listing of status and error messages.
7.
Once the download is complete:
Informative Messages
Host Operations Complete.
Power Down Control.
Disconnect Serial Channel Then
Restart the Control.
Error Messages
Control Screen
Connection established.
Device is a 9/290 CNC
Downloading required system modules...
Module:
Boot Directory
Revision 1.0 Status: downloaded
Module:
XLINX Data
Revision 1.0 Status: downloaded
Module:
Main CPU Exec
Revision 1.0 Status: downloaded
Module:
I/O CPU Exec
Revision 1.0 Status: downloaded
Download complete.
The CNC system is now ready to use.
Power down the CNC.
Disconnect the RS-232 cable.
Then restart the CNC and check the updated system.
If there are problems, the update may be retried.
Retry update (y/n)?
PC Screen