Filtering power for a 9/440 system, Connect the power line filter to c55 as shown – Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual
Page 875

Section 17
Installing 9/Series Hardware for CE Compliance
17-3
Filtering Power for a 9/440 System
To comply with CE guidelines you need to connect a power line filter to
cable C55. The type of filter you need is:
Product
Part Number
Manufacturer
Phone Number
Power Line Filter
MIF323-GS
Roxburgh Electronics LTD
Foxhills Industrial Park
Scuntharpe
South Humberside, DN158Q5
United Kingdom
011-44-017-242-81770
Connect the power line filter to C55 as shown:
Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C55
9/440
External 380/460V Three Phase
Drive Power
9/440 System Module
Power Terminal Block
Prepared by Customer
DC+
INT
COL
W1
W2
U
W
V
PE
9/440 Power Strip
Noise suppressor
AC Bulletin 100--A30N x 3 (surge protector required) or
DC Bulletin 100--A30NZ x 3
Bussman FRS--R--20A (min) 600 V AC
FRS-R-30A (max) 600V AC
or equivalent (qty 3)
Three-phase input
380-460V AC
Bulletin 100
Contactor Power
C
55
E-STOP Status Contactor
(customer supplied or internal 9/440 TB1 status)
LO
AD
LI
NE
Power
Line Filter
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
Miscellaneous
See Local Codes
(12Awg max)
Clamped by terminal screws
Line Drop Limitation