Section 15B

Replacement Procedures

15B-25

To replace the monochrome CRT:

1.

Turn OFF all power to the control.

ATTENTION: To guard against electrical shock hazards, never

make connections or disconnections at the AC distribution

network unless the main AC disconnect switch is open and

locked.

2.

Remove the cover on the back of the monochrome operator panel.

3.

Disconnect the cable running from the main power supply to the

operator panel power supply.

4.

Disconnect the cable running from the operator panel power supply to

the monochrome CRT.

5.

Remove the 4 screws on the sides of the monochrome CRT enclosure.

6.

Slide the monochrome CRT out of the monochrome operator panel

enclosure and replace it with a new monochrome CRT.

7.

Replace and tighten the 4 screws, reconnect the cable running from

the operator panel power supply to the monochrome CRT, replace the

rear cover, then reconnect all additional cables and modules.

To replace the color CRT:

1.

Turn OFF all power to the control.

ATTENTION: Make sure that all cables are properly attached

to the correct terminals. Failure to do so may result in injury to

personnel, or damage to the control or machine.

2.

Remove the cover that covers the rear of the color operator panel.

3.

Disconnect the cable running from the main power supply to the

operator panel power supply.

4.

Disconnect the cable running from the color CRT to the operator

panel power supply at the molex connector.

15B.9

Replacing the Monochrome

CRT

15B.10

Replacing the Color CRT