Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual
Page 846

Error and System Messages
Section 16
16-26
Message
Description
MEMORY CRASH - REFORMAT
A major error has occurred within the system RAM memory. All part programs stored in memory
will have to be be deleted by performing a reformat operation. This will not remove the current
versions of AMP or PAL from the system.
MEMORY FULL
There is no more RAM memory space for part program storage. If you are in the process of
editing a part program, your changes cannot be saved.
MIDSTART NOT ALLOWED FROM TAPE
You cannot perform a mid-program start on a program that is stored on tape. The program must
first be transferred to RAM memory.
MINIMUM RPM LIMIT AUXILIARY SPINDLE 2
The commanded aux spindle 2 speed requested by the control is less than the AMPed minimum
aux spindle 2 speed for the current gear being used. This requires a gear change operation or a
change in the programmed aux spindle 2 speed. In some cases, the OVERRIDE> switch may be sufficient. MINIMUM RPM LIMIT AUXILIARY SPINDLE 3 The commanded aux spindle 3 speed requested by the control is less than the AMPed minimum aux spindle 3 speed for the current gear being used. This requires a gear change operation or a change in the programmed aux spindle 3 speed. In some cases, the OVERRIDE> switch may be sufficient. MINIMUM RPM LIMIT FIRST SPINDLE The commanded spindle 1 speed requested by the control is less than the AMPed minimum spindle 1 speed for the current gear being used. This requires a gear change operation or a change in the programmed spindle 1 speed. In some cases, the OVERRIDE> switch may be sufficient. MINIMUM RPM LIMIT PRIMARY SPINDLE The commanded primary spindle speed requested by the control is less than the AMPed minimum primary spindle speed for the current gear being used. This requires a gear change operation or a change in the programmed primary spindle speed. In some cases, the MINIMUM RPM LIMIT SECOND SPINDLE The commanded spindle 2 speed requested by the control is less than the AMPed minimum spindle 2 speed for the current gear being used. This requires a gear change operation or a change in the programmed spindle 2 speed. In some cases, the OVERRIDE> switch may be sufficient. MINIMUM RPM LIMIT THIRD SPINDLE The commanded spindle 3 speed requested by the control is less than the AMPed minimum spindle 3 speed for the current gear being used. This requires a gear change operation or a change in the programmed spindle 3 speed. In some cases, the OVERRIDE> switch may be sufficient. MIRROR NOT ALLOWED ON ROLLOVER AXIS You cannot perform mirrored motion using an axis with rollover. MISSING 1394 I/O RING ADDR This message indicates that a 1394 amplifier ID has been AMPed but not defined in I/O ring assignment from ODS. The 1394 amplifier must be a defined device on the 9/Series fiber optic I/O ring. MISSING ( [ ) AFTER FUNCTION NAME Paramacro and calculator functions must have their values enclosed in [ ], for example, SIN[5]. MISSING ( ] ) Paramacro and calculator functions must have their values enclosed in [ ], for example, SIN[5]. The control has found that a right bracket “]”is missing in the current operation. MISSING (END) COMMAND The control has found an end-of-program block (M02 or M30) before it has read the END command for a paramacro DO loop. MISSING (F) IN INVERSE TIME An F-word must be programmed in every motion block that is not rapid when in inverse time feed mode (G93). F is not modal in G93. MISSING (GOTO) COMMAND An IF paramacro condition does not have a GOTO with a sequence number following the condition. MISSING A (DO) COMMAND A WHILE paramacro condition does not have a DO with a loop identifier following the condition. MISSING ADAPTIVE FEED DATA An attempt was made to create a transfer line part program from the quick view screen with incomplete adaptive feedrate data. MISSING COMMA An error occurred in G05 DH+ communications block. MISSING COMMA OR RIGHT PARENTHESIS An error occurred in G05 DH+ communications block.