I/O Interface
Section 10A
10A-49
You can place several 1746I modules with 1746 I/O chassis in the 9/Series
fiber-optic ring. Each 1746 I/O chassis must contain its own 1746I module
(daisy chaining racks together using one 1746I module is not allowed).
The number of I/O points/chassis is limited to the number of ASRN chips
supported by the 9/Series fiber--optic ring. Use page 10B-10 to calculate
how many ASRN chips are required for each I/O chassis. A maximum of
16 chassis are allowed on the 9/Series fiber-optic I/O ring.
1746I adapter module
1746 Series B I/O Chassis
Three different fully equipped 1746 I/O chassis are available for the
9/Series I/O ring. These chassis contain the following I/O devices:
Table 10A.AJ
Standard 9/Series 1746 I/O Catalogs
Catalog Number
8500-S115
Catalog Number
8500-S24
Catalog Number
8500-SANL
(1) 1746-A4
4 Slot Chassis
(1) 1746-A4
4 Slot Chassis
(1) 1746-A4
4 Slot Chassis
(1) 1746-P1
115/230V ac Power Supply
(1) 1746-P1
115/230V ac Power Supply
(1) 1746-P1
115/230V ac Power Supply
(1) 8500-1746I
I/O Ring Interface Adapter
Module
(1) 8500-1746I
I/O Ring Interface Adapter
Module
(1) 8500-1746I
I/O Ring Interface Adapter
Module
(2) 1746-IA16
16 point 115V ac Input
Module
(2) 1746-IB16
16 point 24V dc Input Module
(1) 1746-NIO4V
Analog Input Module
(1) 1746-OA16
16 point 115V ac Output
Module
(1) 1746-OW16
16 point 24V dc Output
Module
(1) 1746-N2
2 Empty Slot Covers
(1) set fiber optic
connectors
for connection to I/O ring
(1) set fiber optic
connectors
for connection to I/O ring
(1) set fiber optic
connectors
For connection to I/O ring
Total I/O
32 115V ac Inputs
16 115V ac Outputs
3 ASRN chips
Total I/O
32 24V dc Inputs
16 24V dc Outputs
3 ASRN chips
Total I/O
2 analog input chnls.
2 analog output chnls
6 ASRN chips
10A.6